Magnetic Level Gauge Inspection and Test Plan 

This article provides you with a sample magnetic level gauge inspection and test plan. You need to modify this ITP to meet your purchase order specifications.

Magnetic Level Gauge Inspection and Test Plan TaskVendorTPI InspectionClient
Magnetic level gauge mill test reportHRR
Magnetic level gauge Calibration check including hystersisHWR
Magnetic level gauge Insulation resistance testHWR
Magnetic level gauge System level functional test (e.g. configuration capability, diagnostic, etc)HWR
Magnetic level gauge Final visual / Dimension InspectionHHR
Magnetic level gauge Documentation review prior to release(Final activity of Technical Inspection)HHR
Magnetic level gauge Pre-shipment InspectionHHR

Magnetic Level Gauge Inspection and Test Plan Points

H: Hold Point implies that relevant production activities shall not proceed until the continuation of work is permitted by Purchaser. (Notification req'd)

W: Witness point implies that Purchaser intends to witness the designated inspection feature. If Purchaser decides not to witness the relevant feature, production can proceed without permission of Purchaser. (Notification req'd)

S: Witness, but spot check basis. Initial operation will be witness point and subsequent operation will be witnessed at discretion of Purchaser considering the results of previous inspection. (Notification not req'd : Randam Inspection)

R: Review inspection & test records (Notification not req'd)

General Note for Magnetic Level Gauge ITP :

1) Magnetic Level Gauge witness/hold point by Code Inspector, when applied by Code /Local Regulation, is to comply with its requirements and to specify in Vendor's ITP.

2) Type of Inspection by Magnetic Level Gauge Purchaser may be changed according to equipment criticality and vendor QC evaluation at job stage.

3) When requested in the requisition, detailed Magnetic Level Gauge ITP shall be submitted by Vendor.

4) Monitoring/Observation of Magnetic Level Gauge Vendor shop daily routine works (i.e. Storage of materials, Adherence to approved procedures, Testing tool calibration check, workmanship, cleanliness and etc.) shall be done by Purchaser during inspection visit.

5)100% Magnetic Level Gauge inspection which is covered by the combination of witness / spot check / record review inspection & tests listed above and vendor's original QC activity shall be confirmed by Purchaser's inspector prior to shipment.

6)Unless otherwise specified in Magnetic Level Gauge REQ., the sampling Q'ty of " S (Spot Witness Check) " shall be as follows:

3 to 20→3Pcs(all if total 2 and less) , 21 to 50→5Pcs, 51 to 100→10Pcs,101 to 200→20Pcs, 201 to 300→30Pcs, 301 to 500→50Pcs

Minimum 25 pcs or more of the commodity shall be arranged for H/W/S inspection and test at one time inspector's visit as much as practical.

7)Final Magnetic Level Gauge Visual Inspection/Documentation Review/Pre-Shipment Inspection may Pre be combined within one time visit.

 

Free newsletter!